Rotary C.B. Union - High Temperature (Sizes 1/4" to 1-1/4")
Installation Procedures
• A suitable run-in period before fitting is recommended. Rotate the C.B. at 150 r.p.m. for 30 minutes. • Add system liquid if seals squeak. • A torque arrestor may be fitted, but this must not restrict the rotary union. • Ensure that the spindle thread is RH or LH to suit the direction of rotation of the machine shaft. • If the machine shaft reverses direction of rotation, securely lock the spindle or (preferably) use a flanged connection. • DO NOT fix valves etc. directly on to the rotary union. • DO NOT connect with rigid pipe. • DO NOT clamp the rotary union.
Maximum Length For Flexible Hose
Back to Models Page Back to Filton® Home Page
|
|
|||||||||||||||||||||||||||
|
|
|
|
|
|||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||